BATTERIES
The 24VDCPS uses 2 AA batteries. Recommended batteries are Lithium (non-rechargeable), Alkaline, or NiMH (rechargeable). To avoid damage by over-dis-
charging, rechargeable batteries should be removed when the Low Battery LED
() illuminates. Non-Rechargeable batteries may continue to be used until
the Red Fault LED
(
) illuminates, at which time the output voltage will have fallen below 24 V. Lithium batteries are recommended for best performance in
cold weather operations.
Typical Battery Life (Conditions: 12 mA loop current, 23° C)
Battery Chemistry Type Examples Typical Battery Life (hours)
Low Battery Indication
()
Lithium Non-Rechargeable Energizer Ultimate
14.5
(10 hrs at -20° C)
2 minutes remaining at 24 V output
5 minutes until output drops below 18 V
Alkaline Non-Rechargeable
Rayovac Max Plus 815
Duracell MN1500
Energizer E91, EN91
6
30 minutes remaining at 24 V output
40 minutes until output drops below 18 V
NiMH Rechargeable Energizer Recharge 9 Remove batteries immediately
NiMH (Low Self Discharge) Rechargeable Sanyo Eneloop 7.5 Remove batteries immediately
!
CAUTION: Do not use AA sized, 3.6 V Li-Ion batteries in the 24VDCPS. Doing so will damage the device.
Battery Replacement
Remove the protective boot and slide the battery cover o. Replace the batteries, taking care to note the correct polarity.
For best results, always replace batteries in pairs. Do not mix fresh and old batteries or batteries of dierent types.
!
CAUTION: To avoid damage by over-discharging, rechargeable batteries should be removed immediately when the Low Battery LED () illuminates.